When using a Huaquan generator, the following key points should be noted to ensure safe operation and extend equipment usage time:
Huaquan generator
1、 Inspection before starting the Huaquan generator
Huaquan generator oil inspection, oil: Ensure that the oil level is within the range of the scale and replace it regularly. Coolant: Check the water tank level to avoid engine overheating. Fuel: Use clean diesel that meets the standards, fill the fuel tank to a reasonable capacity, and avoid impurities blocking the oil circuit.
Electrical system inspection, check if the battery is fully charged and if the wiring terminals are securely fastened to avoid startup failure. Ensure that the output circuit has good insulation and no risk of damage or short circuit.
Mechanical status, check the tightness of the belt and the tightness of the screws to prevent loosening or falling off during operation.
 
2、 Precautions for starting and operating Huaquan generator
Start up operation, preheating is required during cold start to avoid direct high load operation. Run without load for 3-5 minutes after starting, and gradually load after the water temperature and oil pressure stabilize.
Operation monitoring, voltage/frequency: Ensure stable output and avoid damaging electrical equipment. Temperature and oil pressure: refer to the manual for details. Load management: Overloading is strictly prohibited, and it is recommended that the load not exceed 80% of the rated power; The three-phase load needs to be balanced.
Ventilation and heat dissipation ensure good ventilation in the operating environment, avoiding the accumulation of carbon monoxide or engine overheating. Regularly clean the radiator dust to prevent blockage.
Huaquan generator
3、 Huaquan Generator Shutdown Operation Specification
Gradually unload the load and run it without load for 3-5 minutes before turning off the engine to avoid sudden stop and component damage. Close the fuel valve, check for oil leaks, water leaks, or abnormal vibrations, and record operating data.
 
4、 Daily maintenance and upkeep of Huaquan generators
Regularly replace the filter element, oil filter element: Replace it synchronously with each oil change., Diesel filter element: Replace every 200-300 hours to prevent oil blockage. Air filter: Regularly clean or replace according to the cleanliness of the environment.
Huaquan generator battery maintenance, disconnect the negative terminal of the battery when it is not in use for a long time, charge it once a month, and prevent sulfurization.
Long term storage, empty the fuel tank and oil circuit to prevent diesel from deteriorating. Store in a dry environment, covered with a dust cover, and start every 3 months.
Huaquan generator
Please refer to the manual of Huaquan Generator for specific operations, or consult. Different models may have differences, and regular professional inspections and maintenance are required.
More information on Huaquan generators:http://www.huaquan98.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD