The daily maintenance of weichai diesel generator set is an important measure to ensure their stable operation and extend their service life. The following are the main items for daily maintenance and upkeep:
一、 Daily cleaning and maintenance of weichai diesel generator set
Keep the exterior of the generator set clean and regularly use a soft cloth or brush to remove dust and dirt from the surface, especially from the radiator and air inlet. Secondly, check the oil level, cooling level, and fuel quantity of the generator set to ensure that these critical fluids are at normal levels and to avoid damage to the generator due to lack of lubrication, cooling, and fuel.
二、 Regular replacement and inspection of weichai diesel generator set
1. Oil and Filter: Regularly change the oil and replace the oil filter at the same time to ensure the cleanliness and lubrication performance of the oil. The replacement cycle is usually determined based on the frequency of use and working environment of the generator set, and it is recommended to replace it every 250-300 hours of operation.
2. Air filter: The air filter can filter out dust and impurities in the air, protecting the precision components inside the generator set. It is recommended to clean the air filter every 250 hours of operation and replace it every 500 hours of operation.
3. Fuel filter: The fuel filter can filter out impurities in the fuel, ensuring the purity of the fuel. It is recommended to replace the fuel filter every 250 hours of operation.
三、 Weichai diesel generator system inspection and testing
1. Cooling system: Check the water pipes, radiators, and water pumps of the cooling system to ensure that there are no leaks or blockages. At the same time, regularly check the quality and concentration of the coolant to ensure the cooling effect.
2. Fuel system: Check the fuel lines, fuel pumps, and injectors to ensure there are no leaks or blockages. At the same time, pay attention to the quality and storage methods of fuel, and avoid using expired or inferior fuel.
3. Battery and Wires: Check the battery level and voltage to ensure that the battery is in good condition. At the same time, check the wiring connections of the generator set to ensure that there is no damage or poor contact.
4. Engine: Check the operation of the engine, including sound, vibration, and temperature. If there is any abnormality, the machine should be stopped in time for inspection and troubleshooting.
四、 Other precautions for weichai diesel generator set
1. Regularly conduct load tests on the generator set to ensure stable operation under various loads.
2. Pay attention to the storage environment of the generator set and avoid unfavorable factors such as humidity, high temperature, and direct sunlight.
3. Regularly inspect the protective devices and safety signs of the generator set to ensure that they are intact and undamaged.
Through the above daily maintenance measures, the stable operation and extended service life of weichai diesel generator set can be guaranteed.