The precautions for proper shutdown of Diesel Generator are as follows:
Diesel Generator
1、 Normal shutdown steps for Diesel Generator
Gradually unload the load: Before shutting down, the load on the Diesel Generator should be gradually reduced.
Slow down and run without load: Adjust the speed controller to the low speed position and let the diesel engine run in an unloaded state for 3 to 5 minutes.
Turn off power and fuel supply: After running without load for a period of time, turn off the power switch of the generator. Adjust the throttle to the lowest position and cut off the fuel supply.
Maintenance after shutdown: After shutdown, start the fuel supply pump and run it for two minutes to replenish lubricating oil and dissipate heat in the high-temperature area of the diesel engine.
Check the condition of each component of the Diesel Generator and clean the dust from the air filter element.
Check the oil level and add oil if necessary.
Check the cooling water level in the water tank and add soft purified water if necessary (note: the check is only effective after 15 minutes of shutdown).
Diesel Generator
2、 Diesel Generator emergency shutdown operation
Emergency situation identification:
When the Diesel Generator encounters the following situations, an emergency shutdown is required immediately:
Abnormal noise or vibration: may be caused by loose components, wear, or other malfunctions.
Damaged parts lead to serious malfunctions.
The moving parts such as piston, crankshaft, connecting rod, and governor are stuck.
The cooling system of the Diesel Generator has malfunctioned, causing the generator set to overheat.
Abnormal oil system, such as low or high oil pressure.
Electrical system faults, short circuits, leakage, and other situations.
Emergency stop operation:
Press the red emergency stop button directly on the machine.
After emergency stop, turn the control knob to the "Stop" position and rotate the emergency stop button clockwise to reset.
Diesel Generator
Following the above precautions can ensure that the Diesel Generator is shut down correctly, extend the unit's service life, and can operate normally in the next use.
More information on Diesel Generator:http://www.huaquan98.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD