Keeping the Hospital generator in good working order requires strict adherence to maintenance protocols. Key daily procedures must be followed to ensure the Hospital generator provides uninterrupted emergency power when needed. It is hoped that the following introduction will serve as a reference for users.
Hospital generator
‌1. Scheduled Operational Testing‌ of the Hospital generator
Conduct weekly no-load startups of Hospital generator to verify instant activation capability. Monthly, perform 30-minute loaded tests under at least 30% capacity to exercise all systems. Document voltage/frequency stability during these tests in maintenance logs.
 
‌2. Fluid System Management‌
Check oil levels in Hospital generator before each scheduled operation using manufacturer-specified viscosity grades. Replace fuel filters quarterly and always maintain diesel tanks above 80% full to minimize condensation. Test coolant concentration biannually with refractometers.
 
‌3. Electrical Components Inspection‌ of the Hospital generator
Monthly, inspect all wiring connections in Hospital generator control panels for corrosion or looseness. Verify battery terminal cleanliness and charge levels, cleaning with baking soda solution when needed. Test automatic transfer switches semiannually during planned power outages.
 
‌4. Mechanical System Care‌
Monitor vibration levels during operation as early indicators of bearing wear in Hospital generator. Lubricate throttle linkages annually with high-temperature grease. Check belt tension and alternator brushes every 500 operating hours.
 
‌5. Environmental Considerations‌
Keep Hospital generator rooms clean with HEPA-filtered positive air pressure. Install moisture absorbers in humid climates and rodent deterrent systems in all installations. Never store flammable materials within 3 meters of operating units.
 
These maintenance activities can ensure the reliability of Hospital generator. Properly maintained emergency power systems not only protect the equipment; they also safeguard patients' lives in critical situations.
More information about Hospital generator:http://www.huaquan98.com/

Sales hotline: +86 15905360672
WeChat customer service: +86 15905360672
Email address: huaquan@huaquanpower.com
Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone, Weifang City, Shandong Province
Company Name:SHANDONG HUAQUAN POWER CO.,LTD